yellow snow

New member
First time I have ever had product "crash" I know I have seen this before, but I can't seem to find what I am looking for using the search button.

How you do deal with product that has crashed. I know you have to heat it, but was wondering if anyone has the specific details?
 
First time I have ever had product "crash" I know I have seen this before, but I can't seem to find what I am looking for using the search button.

How you do deal with product that has crashed. I know you have to heat it, but was wondering if anyone has the specific details?
Use blow dryer or hold under lite candle.
Just close enough to get hot until it all is good!!


Sent from my SAMSUNG-SM-G890A using Tapatalk
 
First time I have ever had product "crash" I know I have seen this before, but I can't seem to find what I am looking for using the search button.

How you do deal with product that has crashed. I know you have to heat it, but was wondering if anyone has the specific details?
It prolly crashed with temp change!
If it's test cyp it will do it unless dosed 200mg or less but still in cold!!

But all u gotta do is heat it up.
I like the candle method the best.
U may need to hold with something because it can get hot to touch but this best and fastest!!
With things that crash Dailey to eod this is best.

U don't need to vent or do anything just move away and lightly flip up and down to mix well as bottom gets hottest!!

Once done u can soak in hot water to get cool enough to pin.
Keep top above water!!

I have seen blow dryer take long and water method too!!

The candle flame!!! Best. Label won't even get damaged if done careful!!

Good luck!!! This is best way and works when mixing 2 types of gear as well into one vial to get as one together!!!

Sent from my SAMSUNG-SM-G890A using Tapatalk
 
It's happened to me a few times. I just put it in some warm water. Goes back into solution within minutes.
 
It will continue to crash until you heat it to its melting point i believe. Then it should stay suspended.

And was it a prescription testosterone that crashed? Mine says right on it "Warming and shaking the vial should redissolve any crystals that may have formed during storage at temperatures lower than recommended.

I was actually surprised to see that on the box my Testosterone Cypionate came in. I guess i just figured that only Under ground Labs Gear crashed, Never would have thought actual Pharmaceutical grade gear would do so.
 
It will continue to crash until you heat it to its melting point i believe. Then it should stay suspended.

And was it a prescription testosterone that crashed? Mine says right on it "Warming and shaking the vial should redissolve any crystals that may have formed during storage at temperatures lower than recommended.

I was actually surprised to see that on the box my Testosterone Cypionate came in. I guess i just figured that only Under ground Labs Gear crashed, Never would have thought actual Pharmaceutical grade gear would do so.

it was UGL stuff my watson from the pharmacy never has crashed, but then again it is only 200mg/ml vs 300mg/ml.

- - - Updated - - -

What really sucks is I like to preload 3-4 weeks worth of slin pins for my TRT and do them 2xw at .5cc.................This is going to suck to heat shit up every 3 days. I may try taking it to 190 degrees in a pan of water and see if it suspends.
 
I have heated primo ace 100mg that crashed.
I put Mit on held over burner close till all good. Nothing else would get hot enough to melt all primo ace! Didn't touch bottle of burner just held close, didn't think of candle back then....
I got a primo 100 e and did same.
Once cool enough I took out 5ml of each and added to other.
Never crashed again and it would everyday the primo ace!!!

Just an idea for u to mix with another type of testosterone that isn't crashing even a test e or c.... with your crashed one.

Or u can add a little bb around 2-4% more to vial heat up and should be ok!!!

I did that before too. Sometimes they try to get away with 2%BA and 7% BB!!
Not gonna happen with raws from certain places....
2% BA and 15% BB causes no problem and holds it!!!
90% of time problem is that...
18% BB even ok especially with 300 cyp

I never would want a test cyp over 250mg

Sent from my SAMSUNG-SM-G890A using Tapatalk
 
Warm tapwater and patience is all you need :)

Don't put it in the microwave or put direct heat on it.
 
it was UGL stuff my watson from the pharmacy never has crashed, but then again it is only 200mg/ml vs 300mg/ml.

- - - Updated - - -

What really sucks is I like to preload 3-4 weeks worth of slin pins for my TRT and do them 2xw at .5cc.................This is going to suck to heat shit up every 3 days. I may try taking it to 190 degrees in a pan of water and see if it suspends.

Ok i thought you were talking about your prescription pharma grade, which surprised me, but i guess it can happen but glad it wasnt the case and it was your UG testosterone.

And im guessing 190 degrees is the melting point for this since you posted that? I am curious to see how it went after reaching the 190 mark or whatever the melting point is
 
You really don't have to heat it up to 190 degrees since oil, ba and bb helps dissolve the powder.
 
Back
Top