Presser

Admin
Staff member
Administrator
Moderator
[FONT=arial, helvetica, sans-serif]
[/FONT]
[h=2]Powder Conversion Recipies[/h]
Here are some recipes I found that I think need to be looked at. These are very good recipes and should help out many. Remember, unless you're putting a very small mg/ml in your brew then you should be better off to use 18 to 20 % BB. These recipes are set up for a 50% Ethyl Oleate (co solvent and sort of an oil) and 50% Grape Seed Oil as this oil is thinner than Sesame and makes for smoother injections not to mention that it is healthier (has vitamins and stuff sesame doesn't Yippppeeeee!) You can use pure EO if you want it will hold stuff in suspension better (wont crash as easy). It's expensive but worth it if you have the money. There is no steps to conversion here because all of them are the same! The way you cook your brew now (unless you're doing it wrong) is the way you brew this.
Have fun!!!!!


Test E/C/D, Deca, Eq, Tren E, Primo E 50mls @ 200mgs/ml
10g powder
17.5ml Ethyl Oleate (EO)
16ml Grapeseed Oil (GSO)
1.5ml BA (3%)
7.5ml BB (15%)

Test E/C/D, Deca, Eq, Tren E, Primo E 40mls @ 250mgs/ml
10g powder
13.3ml EO
12 ml GSO
1.2ml BA (3%)
6ml BB (15%)

Test E/C/D, Deca, Eq 40mls @ 300mgs/ml
12g powder
11.8ml EO
10ml GSO
1.2ml BA (3%)
8ml BB (20%)

Test E/D, Deca, Eq 30mls @ 333mgs/ml
10g powder
10ml EO
5.6ml GSO
.9ml BA (3%)
6ml BB (20%)

Test Prop (TP)/PhenylProp (TPP), Tren A, Masteron, Npp 100mls @ 100mg/ml
10g powder
37.5ml EO
37ml GSO
3ml BA (3%)
15ml BB (15%)

Test Phenylprop, Masteron, Npp 60mls @ 150mg/ml
9g powder
25ml EO
14.5ml GSO
1.8ml BA (3%)
12ml BB (20%)

Test PP, Masteron, NPP 60mls @ 166mg/ml
10g powder
25ml EO
13.7 GSO
1.8ml BA (3%)
12 ml BB (20%)

Cut Stack (test p 75mg/ml, tren a 50mg/ml, masteron 50mg/ml) 40mls @ 175mg/ml
3g test prop powder
2g tren a powder
2g masteron powder
15ml EO
10.6ml GSO
1.2ml BA (3%)
8ml BB (20%)

Mass Stack (Test E 150mg/ml, Deca 100mg/ml) 40mls @ 250mg/ml
6g test E powder
4g deca powder
13ml EO
12.3ml GSO
1.2ml BA (3%)
6ml BB (15%)

Sustanon 100mls @ 250mgs/ml
10g test dec
6g test iso
6g test phenyl
3g test p
32ml EO
31.25ml oil
3ml BA (3%)
15ml BB (15%)

Sustanon 100mls @ 350mgs/ml
13g test dec
8g test iso
8g test phenyl
6g test p
30.75mls EO
20mls GSO
3ml BA (3%)
20ml BB (20%)

TP(PP)/NPP stack (test p/pp 75mg/ml, npp 50mg/ml) 40mls @ 125mg/ml
3g test p/pp powder
2g npp powder
15.1ml EO
12ml GSO
1.2ml BA (3%)
8ml BB (20%)

Test Acetate (A), P, or PP/Tren A stack (test A/P/or PP 75mg/ml, tren a 50mg/ml) 40mls @ 125mg/ml
3g test a/p/pp powder
2g tren a powder
15.1ml EO
12ml GSO
1.2ml BA (3%)
8ml BB (20%)

Winstrol Recipe#1
50ml @ 50mg/ml
2.5g powder
8ml BB
2.5ml BA
1ml peg 300
.5ml poly
mix powder, bb, ba, and poly and heat at 325 degrees until dissolved, filter, and add 39ml distilled water and re-filter.

Winstrol recipe #2
20mls @ 50mg/ml
1g powder
4.8ml BB
0.6ml BA
0.6ml polysorbate 80
12.5ml distilled water
mix powder, BB, BA, and poly and heat until dissolved. filter, add water and re-filter


Winstrol recipe #3 Oil based (never done this but i trust the recipe)
20ml @ 50mg/ml
1g winstrol powder
17ml oil
.2ml BA
2 ml guaiacol ("super solvent")
mix powder and guaiacol first then add oil and BA. __________________
thats just like....your opinion, man.
 
Here is something I wanted to add to this thread. This will help when making your conversions and you can adjust the quantity of solvent and carriers as necessary.

*Testosterone Base - 1g Displaces 0.893mL
TestosteronePropionate - 1g Displaces 0.909mL
Testosterone enanthate - 1g Displaces 0.943mL
Testosterone cypionate - 1g Displaces 0.909mL
Testosterone decanoate - 1g Displaces 0.962mL
Testosterone Isocaproate - 1g Displaces 0.935mL
Testosterone Phenylpropionate - 1g Displaces 0.885mL
Trenbolone Acetate - 1g Displaces 0.848mL
Trenbolone enanthate- 1g Displaces 0.909mL
Nandrolone deconate- 1g Displaces 0.962mL
Masterone propionate - 1g Displaces 0.935mL




Something to remember is that some powders are not water or organic material soluble and therefore require a solvent heat mixture to dissolve them, once placed in a carrier they can become separated (like water does in oil) and will not hold saturated in organic substances. Example of these are *test base, methandrostenolone, stanozolol , oxymetholone and oxandrolone. These substances are solvent soluble and not organic material soluble. They must be heated and dissolved in a solvent before mixed with a heated carrier, or heated and pressed into tabs with a filler(binder).

Hope this helps some
 
How low can you go on the BB in standard test?
How about test P? I went 15% and a I had a bad PIP?



Standard test? I need more info. What kind of test? How much BA was added, What was the Mg/ML ration and what was the amount of BA/BB in how many ML's?

15% is high but honestly the Bb is not what causes the PIP, it does effect the travel of the BA and the hormone in the muscle as it is a solvent and acts as a thinner.
 
15% is high but honestly the Bb is not what causes the PIP, it does effect the travel of the BA and the hormone in the muscle as it is a solvent and acts as a thinner.[/QUOTE


Test E 250
200ml batch
30ml BB
3ml BA
150 ml oil
50 G of Raw

Slow heated on a hot plate, .22 filtered. Vials and tops pressure sterilized filled using a 60ml syringe
 
i dont understand the purpose or meaning of displacement ??

I mean if you know where the line is to fill large vial or beaker to for a certain amount of ML's then why do you need to know displacement?

ANother words if your making something thats 100mls, and you know the 100ml marker on the beaker or large vial, then don't you just add the powder, then the ba and bb , let is dissolve, then fill the beaker or vial up to the marked area for 100ml with your oil? I just don't understand what the purpose of displacement math is all about

am i missing something? if so then i would like to know, cause it doesn't make any sense to me so long as you already know where your marker is for however many MLs your making, or am i missing something here
 
EX Test Dec displaces .962 of 1 gram added which in turn displaces 1 ml Well close to it.
After the solution is made the .038 displacement area can be filled with additional powder for more mg/ml ratio or more fluid volume.
its the 1cent that gets put in the change jar, after a high volume it eventually adds up.

Honestly the only reason displacement should be an issue is if it over 1.0 displacement. Most of the common ones are already listed but apparently some are chemists and need to have it extremely accurate but it still doesn't resolve how much is in the filtration process-right?

anyhow, I will list it and see if its that vital.
 
Back
Top