1. #1
    MuscleChemistry Newbie Residency Training

    Join Date
    Sep 2019
    Posts
    2
    Rep Power
    0

    Dumby peristaltic pump filter setup info needed

    hi I am using for years 5 vacuum pumps with metal filteration systems
    but I want to know how the setup for peristaltic works
    want to change to better system
    I saw a thread here about it but there was missing info
    if someone can help me thanks, pm is better
     

  2. #2
    MuscleChemistry Registered Member Board Certified DMD
    Macho313's Avatar
    Join Date
    Oct 2015
    Posts
    527
    Rep Power
    2147484183

    Default

    Quote Originally Posted by johnw1980 View Post
    hi I am using for years 5 vacuum pumps with metal filteration systems
    but I want to know how the setup for peristaltic works
    want to change to better system
    I saw a thread here about it but there was missing info
    if someone can help me thanks, pm is better
    Hey Brother welcome to muscle chemistry. Just a little word to the wise not trying to be a smart-ass but intro is always nice when you join a board before asking questions as such. Shoot me a PM

    Sent from my LM-V405 using Tapatalk
    Thanks johnw1980 thanked for this post
     

  3. #3
    MuscleChemistry Newbie Residency Training

    Join Date
    Sep 2019
    Posts
    2
    Rep Power
    0

    Default

    I am just saying that I have years of experience
    not a newbie (: but thanks
     

  4. #4
    MuscleChemistry Registered Member Board Certified DMD
    Macho313's Avatar
    Join Date
    Oct 2015
    Posts
    527
    Rep Power
    2147484183

    Default

    Quote Originally Posted by johnw1980 View Post
    I am just saying that I have years of experience
    not a newbie (: but thanks
    Na brother that wasn't what I meant. Like I said don't take it the wrong way. I wasn't trying to be a smart-ass at all.

    Sent from my LM-V405 using Tapatalk
    Thanks johnw1980 thanked for this post
     

  5. #5
    MuscleChemistry Registered Member Board Certified DMD
    Macho313's Avatar
    Join Date
    Oct 2015
    Posts
    527
    Rep Power
    2147484183

    Default

    The setup would basically be a beaker with what needs to be filtered any hose going from that through the parelistic pump then to the top of a capsule filter. I would buy a lab stand and connect the capsule filter to a lab stand and sit my media bottle right underneath the capsule filter. Also all these capsule filters you can buy with what they call a filling Bell. A filling Bell is a piece of plastic the covers the bottom of the capsule filter that will also cover the opening to any standard gl45 media bottle for sanitation reasons. You can easily filter 3 to 5000 ml in 20 minutes.

    In no way do I promote this as of course is a very illegal act but as always if someone is going to do something I would like at least to try to keep them safe while doing it..

    Sent from my LM-V405 using Tapatalk
    Thanks johnw1980 thanked for this post
     

  6. #6
    MuscleChemistry Newbie Board Certified D.V.M.
    Tailor's Avatar
    Join Date
    Mar 2017
    Posts
    30
    Rep Power
    0

    Default

    Does parelistic pump with operating pressure around 2.5bar is good enough?
     

  7. #7
    MuscleChemistry Registered Member Board Certified DMD
    Macho313's Avatar
    Join Date
    Oct 2015
    Posts
    527
    Rep Power
    2147484183

    Default

    Quote Originally Posted by Tailor View Post
    Does parelistic pump with operating pressure around 2.5bar is good enough?
    Well it's hard to say but usually depending on the tubing you're using 2.5 bar equals around 35 PSI. Why don't you post a picture of the pump for a link to it so you can get a better answer.

    Also what are you using it for filtering, transferring? stuff like that..

    More importantly I would look at LPM or RPM's...

    Sent from my LM-V405 using Tapatalk
     

  8. #8
    MuscleChemistry Newbie Board Certified D.V.M.
    Tailor's Avatar
    Join Date
    Mar 2017
    Posts
    30
    Rep Power
    0

    Default

    I am think of switching to parelistic pump atm. Currently, vacumm glass funnel in use. Filtering time isn't best, especialy with test e. Wanted to know where to start. Setup what I was thinking about is: beaker, pump, capsule filter, receiver bottle. Cure
     

  9. #9
    MuscleChemistry Registered Member Board Certified DMD
    Macho313's Avatar
    Join Date
    Oct 2015
    Posts
    527
    Rep Power
    2147484183

    Default

    Quote Originally Posted by Tailor View Post
    I am think of switching to parelistic pump atm. Currently, vacumm glass funnel in use. Filtering time isn't best, especialy with test e. Wanted to know where to start. Setup what I was thinking about is: beaker, pump, capsule filter, receiver bottle. Cure
    You got it bro. Beaker, pump, capsule filter, and if you get one with a filling bell you would attach it to a lab stand and have the filling bell sitting over top of a GL45 media bottle.

    Check out a "whattman pollycap 36as with filling bell" on Google and you will see what I mean.

    Any other questions bro?

    Sent from my LM-V405 using Tapatalk
     